CoatZF ESD Low-VOC Dissipative Clear Floor Finish | Static Control | ESD and Non-ESD Floors | 5 Gallon
Starting at $450.00
- Zinc-free
- Static dissipative (1 x 10E6 to < 1 x 10E10 ohms) Coating - ANSI/ESD STM7.1 and ESD TR53
- Low tribocharging (<100 volts) coating - ANSI/ESD STM97.2
- 23% Solids- 2 Coat System** Reduces labor needed for initial install and on-going maintenance of the floor
- Hard, wear resistant – ASTM Standard D2134.93
Overview
- Description
- Additional Information
- Specs
- Coverage Rate
- Chemical
- Application
- Calculator
- More Options
Coat ZF ESD Low-VOC Dissipative Clear Floor Finish
Coat ZF is a state-of-the-art ESD floor maintenance clear finish with inherent static-dissipating properties, specifically formulated for application in computer rooms, electronic assembly areas, telephone sub-stations, or any other area where positive elimination of static electricity is a prime consideration. The unique static-dissipating ingredient is actively linked to the chemical structure of the polymer system, preventing wash-out, or leaching of the static dissipating properties.
Easy maintenance, good gloss, and durability are additional assets of this high-tech anti-static finish. UL listed for slip resistance.
StaticWorx CoatZF floor finish is a hard, impenetrable finish, specially designed for use in high-traffic areas. Unlike most ESD waxes and finishes, StaticWorx CoatZF static-dissipative wax be can be applied to conductive tile and ESD coatings, such as StaticWorx GroundWorx epoxy, and replenished without diminishing the electrical performance of the ESD flooring surface.
Comprised of 18% solids, application is easy and improves productivity. Fast, easy-to-use Coat ZF provides a clean, hospital-like shine, can be applied by the regular cleaning crew, and requires no more work than routine waxing and buffing.
CoatZF is specially formulated for application in computer rooms, electronic assembly rooms, telephone sub-stations, or any area where static control is desired. Cross-linked polymer chemical structure prevents leaching or wash-out of static dissipative properties and provides long-lasting static protection.
Available in 5 gallon pail covering 5,000 sq’ project with 2 coats (2 coats required for proper protection – 3 coats recommended for first time application). Recoat every 2 years or as needed. For an easier removal process of the CoatZF consider using our EcoScrub Floor Stripper/Degreaser.
Note: StaticWorx CoatZF is not intended for use on regular, non-ESD vinyl. While it will contribute some ESD properties, the floor must be tested regularly, as well as after each use.
Note: Some extra high traffic areas may require an initial 3-coat application.
Where Surfaces is Coat ZF Used On?
- Concrete
- Epoxy Coatings
- Polyurethane Sealers
- VCT, SVT, SDT
- Any ESD Tile
- Computer rooms
- Electronic Assembly Rooms
- Telephone Sub-Stations
- Any area static control is desired
Why Coat ZF Clear Dissipatative Sealer?
- Zinc-free
- Static dissipative (1 x 10E6 to < 1 x 10E10 ohms) Coating – ANSI/ESD STM7.1 and ESD TR53
- Low tribocharging (<100 volts) coating – ANSI/ESD STM97.2
- 23% Solids- 2 Coat System**
Reduces labor needed for initial install and on-going maintenance of the floor
- Hard, wear resistant – ASTM Standard D2134.93
- UL listed for slip resistance
- Low VOCs & Tribocharging
- Easy to Apply
- Long-Lasting Static Protection
- Designed for High-Traffic Areas
| Weight | N/A |
|---|---|
| Dimensions | N/A |
SPECIFICATIONS |
|
|---|---|
| Solids | 18% nonvolatile, total active solids 22% |
| VOC | 5 g/L |
| Resistivity - ASTM D257 | 108-9 ohms2 max/cm2 @ 40% relative humidity |
| Static Dissipative | 0.02 second |
| Coverage | System requires 2 coats minimum: 2000 sq'/gallon per coat on tile/epoxy and <2,000 per gallon per coat on concrete |
| Packaging Information | 5 gallon pail |
| pH | 8.4 - 9.0 |
| Gloss 600 | 80+ @ 3 coats |
| Color | Translucent white |
| Slip Resistance (ASTM) | 0.52 minimum |
| Drying Time | 30 - 45 minutes |
| Water Resistance | Good |
| Removability (Gardner) | 75 cycles maximum |
COVERAGE RATE
| Coverage | System Requires 2 Coats Minimum: 2000 Sq’/Gallon Per Coat On Tile/Epoxy And <2,000 Per Gallon Per Coat On Concrete |
CHEMICAL RESISTANCE TESTINGSpot testing per ASTM D1308 for Mustard, Ketchup, Lactic acid, vinegar, and lemon juice were performed and no physical damage to the exposed surface was observed. In 24 hour immersion testing, the following results were observed. |
PERFORMANCE |
|---|---|
| Acetic Acid 10% | Passed |
| Nitric acid 30% | Passed |
| Sodium Hydroxide 50% | Passed |
| Sulfuric Acid 30% | Passed |
| Xylene | Passed |
Product Application: Best results are obtained when StaticWorx CoatZF is applied to surfaces which are 60° F. or warmer and in relative humidity conditions of between 40 – 65%. Remove old finish or wax with StaticWorx EcoScrub Degreaser (stripper). Follow directions on stripper label for application. Optimum appearance and gloss on initial application is obtained with three to five coats of finish. No more than 3 coats should be applied in an 8 hour period. Apply thin even coats, allowing the finish to dry, depending on humidity and temperature for approximately 30 – 45 minutes between coats.
For optimum results do not apply during humid conditions, and do not dry-buff or burnish
Recoat: Effective recoating of existing finish may be achieved in the following manner. Vacuum the floor to remove any loose dirt or dust. Wash the floor with StaticWorx ScrubWorx 20.20 to remove dirt and soil. Apply thin even coats, allowing the finish to dry, for approximately 30 minutes before resumption of foot traffic. The frequency of stripping and refinishing will vary somewhat depending on the environmental conditions within a particular facility, but field experience indicates that monthly refinishing
generally provides optimum results
Floor Cleaning: A routine maintenance program will provide the most satisfactory gloss retention and wear characteristics in any floor coating. Floor surfaces should be swept with an untreated mop daily to remove abrasive loose dirt and sand. Floors should be damp mopped with StaticWorx ScrubWorx 20.20 regularly, as needed, to remove soil, salt, and film deposits which can degrade the coatings’ conductive properties and gloss.
5 Step Static Killer Program - Ongoing Maintenance
- Remove any waxes or polishes from your old floor using StaticWorx EcoScrub floor stripper.
- Apply 2 coats of CoatZF per our instructions.
- Measure your floor with our ANSI/ESD S7.1 megohm meter:
Your floor will measure <1.0 X 10 E9.
- Test several high traffic areas every 2 weeks.
- Only clean your floor with StaticWorx ScrubWorx Neutral Cleaner.
Warranty NOTICE TO BUYER: DISCLAIMER OF WARRANTIES AND LIMITATIONS ON OUR LIABILITY
We warrant that our products are manufactured to strict quality assurance specifications and that the information supplied by us is accurate to the best of our knowledge. Such information supplied about our products is not a representation or a warranty. It is supplied on the condition that you shall make your own tests to determine the suitability of our product for your particular purpose. Any use or application other than recommended herein is the sole responsibility of the user. Listed physical properties are typical and should not be construed as specifications. NO WARRANTY IS MADE, EXPRESSED OR IMPLIED, REGARDING SUCH OTHER INFORMATION, THE DATA ON WHICH IT IS BASED, OR THE RESULTS YOU WILL OBTAIN FROM ITS USE. N0 WARRANTY IS MADE, EXPRESSED OR IMPLIED, THAT OUR PRODUCT SHALL BE MERCHANTABLE OR THAT OUR PRODUCT SHALL BE FIT FOR ANY PARTICULAR PURPOSE. NO WARRANTY IS MADE THAT THE USE OF SUCH INFORMATION OR OUR PRODUCT WILL NOT INFRINGE UPON ANY PATENT. We shall have no liability for incidental or consequential damages, direct or indirect. Our liability is limited to the net selling price of our product or the replacement of our product, at our option. Acceptance of delivery of our product means that you have accepted the terms of this warranty whether or not purchase orders or other documents state terms that vary from this warranty. No representative is authorized to make any representation or warranty or assume any other liability on our behalf with any sale of our products. Our products contain chemicals that may CAUSE SERIOUS PHYSICAL INJURY. BEFORE USING, READ THE MATERIAL SAFETY DATA SHEET AND FOLLOW ALL PRECAUTIONS TO PREVENT BODILY HARM.
Square Footage Calculator
Estimate the Right Amount for Your Project
Use the calculator to determine your total project square footage. Once you have your measurements, compare the result to the product coverage rate listed on this page to estimate how much material you'll need for complete coverage.
Calculate Coverage
Quickly determine the total square footage of your project area.
Estimate Product Quantity
Use your results to calculate how much product your project requires.
Plan With Confidence
Add a waste percentage to account for surface texture and application conditions.
Coverage estimates are provided as a general guide. Actual product usage may vary based on surface condition, porosity, application method, and project requirements.
-

EcoScrub Floor Stripper/ Degreaser
- Rinse-free formula
- Low foaming
- No environmentally toxic preservatives
- Low Odor
- Non caustic
-

GroundWorx Basics (SF) ESD Static Conductive Epoxy Floor Coating | Water Based | ANSI/ESD S20.20-2014
- Water - based epoxy, matte finish
- Conductive range 2.5 x 104 - 3.5 x 107 ohms
- System Resistance (w/ ESD Footware) < 3.5 x 107 (fully compliant) ANSI/ESD STM 97.1
- Great low cost solution for concrete, wood, VCT Tile floors
- Extended working time - POT life 40+ minutes
-

GroundWorx Ultra (HB-97.2) ESD Static Conductive Epoxy Basecoat 100% Solids | Forklift Traffic | ANSI/ESD S20.20-2014
- Static dissipative or conductive high build epoxy electrical protection when used with the GroundWorx Ultra ESD Urethane Topcoat, which comes in either dissipative >1.0 x 10e6 ohms or conductive <1.0 x 10e6 ohms electrical resistance, limiting Static Charge Generation to <15 volts
- Great for high traffic, high wear commercial & industrial applications as high build 14 mil ESD system at <$4.00/sq' material cost
- Great for high traffic, high wear commercial & industrial applications
- Use on Concrete, Wood and old VCT surfaces
- Moisture tolerant primer
-

GroundWorx Ultra (HB-97.2) ESD Urethane Top Coat | Static Dissipative or Conductive | ANSI S20.20-2014
- Optional Static conductive <1.0 x 10e6 ohms or Dissipative >1.0 x 10e6 and <1.0 x 10e9 ohms high performance electrical protection, limiting Static Charge Generation to <15 volts
- Great for high traffic (forklift & pallet jack), high wear commercial & industrial applications with high build 14 mil system
- Conforms to ESDA, ANSI standard S20.20-2014 when used with the GroundWorx Ultra ESD Epoxy Primer
- Use on Concrete, Wood and old VCT surfaces
- Tough surface: impact resistance 140 psi and tabor abrasion test 25 mg loss
-

GroundWorx Basics (SF) ESD Static Dissipative Epoxy Floor Coating | Water Based | ANSI/ESD S20.20-2014
- Water - based epoxy, matte finish
- Static Dissipative 10e6 - 10e9 ohms
- Great low cost solution for concrete, wood, VCT Tile floors
- Extended working time - 40+ minutes
- Quick turnaround - Light traffic 12 hours after application
-

GroundWorx Ultra Elevated Moisture Epoxy Primer | For Use In GroundWorx Ultra Epoxy Systems | Zero VOC | Recoat in 5 Hours
- Protects ESD Coatings System from moisture related issues (withstands up to 8lbs of moisture vapor pressure)
- Apply when relative humidity is up to 95%
- Significantly reduce chance of concrete outgassing
- Great for high traffic (forklift & pallet jack), high wear commercial & industrial applications
- Conforms to ESDA, ANSI standard S20.20-2014 when used with the GroundWorx Ultra ESD Epoxy Basecoat and the companion Ultra Urethane Toopcoat
-

ScrubWorx 20.20 ESD Floor Cleaner Concentrate
- Static Conductive
- High Activity Cleaner
- Micro-Cleans & Conditions
- Chemically Seals Tiles
- Simple to Use
You may also like…
-

GroundWorx Ultra (HB-97.2) ESD Static Conductive Epoxy Basecoat 100% Solids | Forklift Traffic | ANSI/ESD S20.20-2014
- Static dissipative or conductive high build epoxy electrical protection when used with the GroundWorx Ultra ESD Urethane Topcoat, which comes in either dissipative >1.0 x 10e6 ohms or conductive <1.0 x 10e6 ohms electrical resistance, limiting Static Charge Generation to <15 volts
- Great for high traffic, high wear commercial & industrial applications as high build 14 mil ESD system at <$4.00/sq' material cost
- Great for high traffic, high wear commercial & industrial applications
- Use on Concrete, Wood and old VCT surfaces
- Moisture tolerant primer
-

GroundWorx Basics (SF) ESD Static Conductive Epoxy Floor Coating | Water Based | ANSI/ESD S20.20-2014
- Water - based epoxy, matte finish
- Conductive range 2.5 x 104 - 3.5 x 107 ohms
- System Resistance (w/ ESD Footware) < 3.5 x 107 (fully compliant) ANSI/ESD STM 97.1
- Great low cost solution for concrete, wood, VCT Tile floors
- Extended working time - POT life 40+ minutes
-

E903UCB Cove Base Urethane Mortar | HIgh Heat 250F | Anti-Fungal
- Easy construction of vertical cove bases
- Seamless hygienic finish with no grout lines
- Resistant fo fungi growth
- Low odor, fast installation, fast cure
- Thermal shock to 250F & chemical resistance