Rainguard Advanced Waterproofer™ 10 Year  protection for homeowners

Advanced Waterproofer is a professional quality clear, colorless penetrating silane siloxane waterproofer designed for homeowners wanting maximum protection against damage from water, salt, stains and weathering.   Using Rainguard’s exclusive Micro-lok technology, it incorporates a multi-use design for a wide variety of homeowner water protection requirements for unpainted vertical & horizontal porous surfaces.  With a 10 year, money back manufacturers guarantee, Waterproofer Advanced is “The Professionals Choice” Available in ready-to-use 1 gallon and 5 gallon containers and money saving concentrates with your choice of a 6 oz Eco-Pod concentrate which makes 1 gallon, a 32 oz concentrate which makes 2 gallons and a 32 oz concentrate which makes 5 gallons of ready-to-use product.  Fast, easy clean up. Simply use soap and water directly after application is completed. Be sure to clean any overspray on glass and decorative metals.

Where is Advanced Waterproofer typically used?

  • Homeowner Projects:  Driveway’s, garage floors, porch’s, patio’s, fences

Why Advanced Waterproofer Water Sealer?

  • Long lasting and virtually indestructible water repellent protection
  • Penetrates deep and will not wear off with heavy vehicle or foot traffic
  • Prevents growth of mold & mildew
  • Does not change the appearance of the surface
  • Stain resistant to oil, gas and anti-freeze
  • Protection for concrete against deicing salts and water infiltration
  • Easy to use – same day, one coat application with hand or airless sprayer
  • Apply in cold weather down to 40°F ( 4.4°C)
  • Water based for easy soap & water clean up
  • 100% Eco-Friendly – Low VOC, low odor, safe to use
  • Protects your investment 10 years with money back guarantee

Technical Information

PRODUCT FEATURES
Color Clear
Sheen/Gloss Level No change in visual appearance
Dry To Re-Coat 60 Minutes
#Coats Recommended 1 or 2 coats depending on level of protection desired and porosity of surface
Back in-service time 1 hours
Application method Low pressure hand pump or airless sprayer
Where Can it be Used All Interior|Exterior unpainted architectural surfaces
Apply to New Concrete 10 days
Low Application Temperature 40F|10C Surface & Air
 Base  Water
VOC Content <15 g/L
Use on Material Concrete, block, brick, masonry, stucco, EIFS, wood
Warranty Available Up to 10 year satisfaction guarantee
COVERAGE RATE SQUARE FEET/GALLON
CMU Precision Block 60-70
CMU Split Face 50-70
CMU Scored/Flute 65-80
CMU Lightweight 40-55
Clay Brick 125-150
Concrete (Dense Masonry) 125-150
Adobe Brick/Natural Stone 70-90
Stucco 100-150
Wood 300
*Extremely porous surfaces  May require 2nd application
*Textured surfaces  Decreases coverage rates

APPLICATION INSTRUCTIONS

CONDITIONS PRIOR TO APPLICATION
Temperature (surface|air) 40F to 90F (4.4C to 35C) and at least 5F above dew point
Moisture of substrate Less than 15%
Humidity Less than 90%
Rain No rain 48 hrs prior to, 12 hrs after application
Cure time for newly poured concrete 2 days
Application method Use low pressure hand pump or garden sprayer

WORKING WITH CONCENTRATES

PART # SIZE MAKES INSTRUCTIONS
TPC-0801 6 oz 1 Gal Empty 6 oz into 1 gal container, fill with water, stir (7 parts water to 1 part Advanced Waterproofer)
TPC-0702 32 oz 2 Gal Empty 32 oz into container and fill with water to the 2 gallon level, stir (7 part water to 1 part Advanced Waterproofer)
TPC-0701 32 oz 5 Gal Empty 32 oz into 5 gal container, fill with water, stir (19 parts water to 1 part Advanced Waterproofer)

FOLLOW THESE SIMPLE APPLICATION STEPS
Clean and Prep:
Before pressure washing apply and brush out stains using Cleaner/Prep manufactured by Rainguard and available here on our website. Ensure the surface is clean and “bone dry”, thus allowing the sealer to absorb into the surface.

Application:
For a proper application, use a hand pumped garden sprayer. Apply 1 (one) heavy saturation coat to ensure the product can penetrate deep into the surface, sealing the pores or capillaries. Once the 1st coat is dry to the touch apply the recommended 2nd saturation coat to ensure best results. Once the 2nd coat is completely dry you can now put any decor, furniture etc. back on the treated surface. IMPORTANT: Avoid letting any water to come in contact with your newly sealed surface for 24 hours. After full cure time is achieved (approximately 4-5 days) you can expect the full beading effect.

Wait to test water repellency after the full chemical cure period. To conduct a test, simply drip some water in a few places where you have sealed the surface, if the drips make the surface darken, this is an indication that it is still absorbing, meaning you need to apply another coating. (more common with older surfaces)

Vertical Surfaces:
Allow product to drip heavily before moving onto the next spot. Heavily saturate the surface maintaining at least a 6-inch drip or run down.

Horizontal Surfaces:
Apply the product until it starts to pool up slightly. You will know enough was applied in any given spot when the product starts to pool (puddle) up with a milky-white color. The puddling will dissipate slowly into the pores so there is no need to back roll or brush them out.

Clean-Up:
Clean-up is a breeze thanks to our water based formula. Simply rinse out equipment with fresh water after application until it runs clear. Any undesired over-spray on windows or glass can be immediately wiped off. If the product has already dried it can be cleaned off quickly with a rag, warm water, and a mild soap.

PRECAUTIONS & LIMITATIONS
1. All surfaces to be coated should be clean of any dirt and grime, efflorescence, lime run, form oils and release agents, grease, mud, excess mortar, and mold and mildew, etc.
2. All cracks should be pointed or caulked. All voids, bee holes, masonry surface defects and openings such as conduits, pipes, drains, door frames, vents, air conditioner openings, electrical openings, control joints, or any dissimilar materials should be repaired using urethane or other approved patching.

STORAGE
Store materials in a well-protected area between 45° and 90°F. Avoid freezing temperatures, direct sunlight, and moisture. Keep away from heat sources.