No products in the cart.
Return To ShopFree shipping Lower 48 States
$80.00 – $346.00
Micro-seal Silane Siloxane Water Repellent | Concrete Brick Block Stucco
CLEAR-SEAL High Gloss Acrylic Urethane Sealer
Why Clear-Seal Urethane Sealer?
TECHNICAL INFORMATIONÂ |
|
---|---|
Color | Clear |
Sheen/Gloss Level | Low gloss |
Dry To Re-Coat | 60 Minutes |
#Coats Recommended | 1 – 3 coats depending on level of gloss and protection desired |
Back in-service time | 24 hours to walk-on |
Application method | Low pressure hand pump or airless sprayer, brush, t-bar, lamb’s wool applicator |
Where Can it be Used | All Interior|Exterior architectural surfaces |
Apply to New Concrete | 10 days |
Low Application Temperature | 50F|10C Surface & Air |
 Base |  Water |
VOC Content | <50 g/L |
Use on Material | All masonry, concrete and wood surfaces |
Warranty Available | 5 year warranty available – Â download warranty application to register, see DOCUMENTS tab above |
Certification/Test | Â |
---|---|
Leed 4.2 (1) point credit available | Meets LEED and SQAMD low VOC requirements |
 |  |
Coverage Rate | Square Feet/Gallon |
---|---|
Porous Surfaces | 200-300 |
Dense Surfaces | 300-400 |
*Textured surfaces | Decreases coverage rates |
Conditions Prior to Application | |
---|---|
Temperature (surface|air) | 50F to 90F (10C to 35C) and at least 5F above dew point |
Moisture of substrate | Less than 15% |
Humidity | Less than 90% |
Rain | No rain 48 hrs prior to, 48 hrs after application |
Cure time for newly poured concrete | Apply 10 days after pour |
Application method | Use low pressure hand pump or garden sprayer, t-bar, brush, lambs wool applicator |
FOLLOW THESE SIMPLE APPLICATION STEPS
1.CLEAR-SEAL Acrylic Urethane Sealer should be applied using either brush, t-bar, lamb’s wool applicator, or most pump-up sprayers. We do not recommend using a roller to apply, as this may allow too much air, causing bubbles to stay in the film.
2.At time of application, moisture content of all surfaces should be 30%or less as measured with an electronic moisture meter.
3.Establish that air, surface and material temperatures are above 40°F (4.4°C) and at least 5°F above the dew point prior to painting. Do not apply at temperatures below 40°F or when temperatures are expected to drop below 40°F within 48 hours of application. Do not apply if rain, snow, or lower temperatures are expected within 48 hours. Do not apply if relative humidity is greater than 80%.
4.Allow at least 1 hour or until tack-free before applying a second coat.
5.Wait 24 hours before opening up to light to moderate traffic, and 72 hours before heavy traffic,
PRECAUTIONS & LIMITATIONS
1. All surfaces to be coated should be clean of any dirt and grime, efflorescence, lime run, form oils and release agents, grease, mud, excess mortar, and mold and mildew, etc.
2. All cracks should be pointed or caulked. All voids, bee holes, masonry surface defects and openings such as conduits, pipes, drains, door frames, vents, air conditioner openings, electrical openings, control joints, or any dissimilar materials should be repaired using urethane or other approved patching.
STORAGE
Store materials in a well-protected area between 45° and 90°F. Avoid freezing temperatures, direct sunlight, and moisture. Keep away from heat sources.
Coverage Rate | Square Feet/Gallon |
---|---|
Coverage Rate | Square Feet/Gallon |
Porous Surfaces | 200 - 300 |
Dense Surfaces | 300 - 400 |
*Textured surfaces | Decreases coverage rates |
$75.00 – $318.00
$21.00 – $43.00
Copyright 2022 by Exterior Performance Coatings