Staticide General Purpose | Static Control for All Surfaces
Starting at $80.00
- Formulated for non-porous surfaces
- Works with our selection of Anti-Static Mats
- Exceeds MIL-B-81705 and NFPA-56A electrostatic decay criteria
- Meets requirements for topical anti-stats as listed in DOD-HDBK-263
- Proven effective in relative humidity below 15%
Overview
- Description
- Additional Information
- Coverage Rate
- Application
- Calculator
- More Options
Staticide General Purpose | Static Control for All Surfaces
Staticide General Purpose anti-static topical is easy to use and highly effective in preventing the build up of electrostatic charge, known as tribogeneration, in industrial manufacturing and static-sensitive environments.
A key component in any static control program, this ready-to-use solution formulated specifically for non-porous surfaces is non-toxic, non-flammable, and non-staining. With a similar viscosity to water, it can be applied in many ways including spraying, wiping, or dipping.
Staticide General Purpose can be used for revitalizing anti-static mats that have lost their dissipative properties and when applied to packaging material, can be classified as low charging packaging material as described in ANSI/ESD S541-2019 when tested according to ESD ADV11.21.
Check out our selection of anti-static mats that Staticide can be used on:
- ESD 640 textured conductive floor mat
- ESD conductive anti-fatigue cushioned floor mat
- ESD conductive anti-static floor runner
- ESD conductive anti-static chair floor mat
Where is Staticide General Purpose used?
- Electronics manufacturing and assembly, ESD protected areas electronic, medical, cleanroom manufacturing facilities
- Reduce dust, dirt, and bacteria attraction to surfaces
- Prevent damage to sensitive electronic equipment, components, and subassemblies during manufacture, testing, packaging, and shipping
- Jamming or slipping of paper, plastics, and other materials during printing, packaging, and converting
- Ignition of combustible vapors, dust, and solvents, preventing fire or explosion
- Irregularities caused by static in quality printing, heat sealing, silk screening, lamination, and other special applications
- Static discharge on workbenches and production surfaces
Why Staticide General Purpose Cleaner ?
- Formulated for non-porous surfaces
- Works with our selection of Anti-Static Mats
- Exceeds MIL-B-81705 and NFPA-56A electrostatic decay criteria
- Meets requirements for topical anti-stats as listed in DOD-HDBK-263
- Proven effective in relative humidity below 15%
- Decays static in less than 2 seconds
- Surface resistance between 10e9 – 10e10 ohms
- One gallon covers approximately 2000 sq ft
- Lasts from weeks to months depending on application
| Weight | N/A |
|---|---|
| Dimensions | N/A |
| Manufacturer | |
| Surface Applied To | |
| Size |
| COVERAGE RATE | SQUARE FEET/GALLON PER COAT |
|---|---|
|
APPLICATION INSTRUCTIONS
Directions:
Staticide® topicals can be applied by spraying, wiping, dipping, transfer roller coating, gravure coating, or flexographic printing. For high production applications, mechanically apply solution by using fine-mist sprayers or foam rollers. The product can also be manually sprayed using a trigger sprayer at 8-12” from desired surface.
⚠ California Proposition 65 WARNING ⚠
This product can expose you to chemicals which are known to the state of California to cause cancer and birth defects or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
NOTICE TO BUYER: DISCLAIMER OF WARRANTIES AND LIMITATIONS ON OUR LIABILITY We warrant that our products are manufactured to strict quality assurance specifications and that the information supplied by us is accurate to the best of our knowledge. Such information supplied about our products is not a representation or a warranty. It is supplied on the condition that you shall make your own tests to determine the suitability of our product for your particular purpose. Any use or application other than recommended herein is the sole responsibility of the user. Listed physical properties are typical and should not be construed as specifications. NO WARRANTY IS MADE, EXPRESSED OR IMPLIED, REGARDING SUCH OTHER INFORMATION, THE DATA ON WHICH IT IS BASED, OR THE RESULTS YOU WILL OBTAIN FROM ITS USE. N0 WARRANTY IS MADE, EXPRESSED OR IMPLIED, THAT OUR PRODUCT SHALL BE MERCHANTABLE OR THAT OUR PRODUCT SHALL BE FIT FOR ANY PARTICULAR PURPOSE. NO WARRANTY IS MADE THAT THE USE OF SUCH INFORMATION OR OUR PRODUCT WILL NOT INFRINGE UPON ANY PATENT. We shall have no liability for incidental or consequential damages, direct or indirect. Our liability is limited to the net selling price of our product or the replacement of our product, at our option. Acceptance of delivery of our product means that you have accepted the terms of this warranty whether or not purchase orders or other documents state terms that vary from this warranty. No representative is authorized to make any representation or warranty or assume any other liability on our behalf with any sale of our products. Our products contain chemicals that may CAUSE SERIOUS PHYSICAL INJURY. BEFORE USING, READ THE MATERIAL SAFETY DATA SHEET AND FOLLOW ALL PRECAUTIONS TO PREVENT BODILY HARM.
Square Footage Calculator
Estimate the Right Amount for Your Project
Use the calculator to determine your total project square footage. Once you have your measurements, compare the result to the product coverage rate listed on this page to estimate how much material you'll need for complete coverage.
Calculate Coverage
Quickly determine the total square footage of your project area.
Estimate Product Quantity
Use your results to calculate how much product your project requires.
Plan With Confidence
Add a waste percentage to account for surface texture and application conditions.
Coverage estimates are provided as a general guide. Actual product usage may vary based on surface condition, porosity, application method, and project requirements.
-
ACL 880 Digital Electronic Megohmmeter ESD Resistance | Resistivity | Very High +/- 2% Precision Accuracy
- High Performance Digital Megohmeter Kit
- Alphanumeric LCD scale shows precise value
- Resistance range: 10³ - 10¹² ohms
- Test voltage range: <10 volt variable: 10³ - 9.9x103ohms 10 volt ± 0.5 volts: 1.0x104- 9.9x105 ohms 100 volt ± <5 volts: 1.0x10⁶ - 9.9x1012 ohms
- Accuracy: 10³ - 10¹⁰ ohms: < ± 2%, ± 2 counts 10¹¹ - 10¹² ohms: < ± 10%, ± 4 counts
-
4000 Acrylic Static Dissipative Clear Floor Finish
- Coverage is approximately 1500 – 2000 sq. ft. per gallon
- V.O.C. is less than 4%
- Solids are 20%± 5%
- UL listed for slip resistance
- Compliant to ANSI/ESD S20.20
-
4010 Acrylic ESD Floor Stripper Concentrate
- Prepares floor for application of acrylic based ESD floor finishes
- No ammonia or phosphates
- Effective in hard or soft water
- Low 6% V.O.C.
- Zero tribogeneration
-
4020 ESD Neutralizer Cleaner Concentrate
- Economical concentrate
- Dilute 1:128 cleaner to water
- Neutral pH 7.2
- Low foam - no streaking formula
- Non-toxic and biodegradable safe for sewage & septic systems
-
4030 ESD Neutralizer Cleaner Ready-to-Use
- Ready-to-use (also available as a concentrate, see 4020)
- Neutral pH 7.2
- Low foam - no streaking formula
- Non-toxic and biodegradable safe for sewage & septic systems
- Non-abrasive
-
4100 ESD Restorer | Cleaner Concentrate
- Lengthens maintenance cycle
- Removes black heel marks
- Revitalizes gloss
- Surface resistivity: 107–109 ohms per square @100 volts
- High solids concentrate
-
4400 ESD Polyurethane Anti-Static Floor & Wall Paint | ANSI/ESD S20.20 | Zero VOC | Reinforcing Fibers
- Provides 100% anti-static control, even at low levels of humidity
- Conforms to ANSI/ESD S20.20-2020 when tested according to ANSI/ESD STM7.1
- Static dissipative: 105 to 108 ohms
- Water based with Zero VOC- 0 g/L
- High physical durability with reinforcing fibers
-
4600 Ultra Static Dissipative Clear Urethane Floor Finish
- High performance with exceptional static control
- For Use on vinyl, linoleum, or ceramic tile
- Offers high gloss, slip resistant & abrasion resistant finish
- More economical than other leading ESD floor finishes
- Resists powdering or flaking, even in dry condidtions
-
4800 Ultra II Static Dissipative Clear Urethane Floor Finish
- Coverage 1,500 - 2,000 sq'/gallon
- Strip cycle 12 -18 months
- Suitable to use on ESD tile, epoxy and concrete floors
- Surface resistivity: 107 - 109 ohms per square (average)
- Low voc
-
6700 Premium ESD Static Dissipative Anti-Static Floor Paint | 9 Colors | ANSI/ESD S20.20-2014
- Static dissipative 10e7 - 10e9 ohms
- Conforms to ANSI/ESD S20.20-2014 when tested according to ANSI/ESD STM7.1
- No hot spots
- Excellent adhesion and color retention
- Good resistance to abrasion, oils and washing
-
6700C Premium ESD Static Conductive Anti-Static Floor Paint | 3 Colors | ANSI/ESD S20.20-2014
- Static conductive 10e3 - 10e6 ohms
- Conforms to ANSI/ESD S20.20-2014 when tested according to ANSI/ESD STM7.1
- No hot spots
- Excellent adhesion and color retention
- Good resistance to abrasion, oils and washing
-
ESD Conductive Vinyl Chair Floor Mat Protects Anti-Static Floors | Meets ANSI 20.20
- Protects ESD Flooring & ESD Paint Investment
- Solid Flat Surface Impervious to Damage from Chair Casters
- Conductive Anti-Static Protection
- Continuous and Permanent Path-to-Ground
- Lifetime Warranty ANSI S20.20 & ANSI S7.1-2005
-
ESD Conductive Floor Runner Protects Anti-Static Floors | Meets ANSI 20.20 | 48″W x 75’L
- Protects ESD Flooring & ESD Paint Investment
- Solid Flat Surface Impervious to Damage from Chair Casters
- Great for Long Workbenches or easy cut to size with utility razor knife: 48"W x 75'L
- Conductive Anti-Static Protection
- Continuous and Permanent Path-to-Ground
-
ESD Conductive Anti-Fatigue Cushioned Floor Mat Protects Anti-Static Floors | Meets ANSI 20.20
- Dissipative 1/2" thick cushioned Anti-Fatigue Floor Mat
- Resistance point to point measures 1x10e5 – 1x10e7 ohms
- Dissipative cushioned under layer
- Smooth surface
- Beveled edges
-
ESD Copper Grounding Strips | ANSI/ESD S20.20 | Conductive Grounding For Floor Paint
- Safely ground floor coating systems
- Meet ANSI 20.20 grounding standards when used in conjunction with proper safety items
- Easy to Apply With Adhesive Backing
- We offer both 1/2" wide and 2" wide copper strips
-
ACL 395 Electrostatic Surface Resistivity ESD Test Meter | Compact Easy to Use
- Four color LED display segments (including warning stage)
- Half decades for greater accuracy
- Rubber rails for increased accuracy, durability and lower maintenance
- Dimensions: 2.8" x 5.1" x 1.4"
- Conforms to ASTM D257
-
ACL 800 Digital Electronic Megohmmeter ESD Resistance | Resistivity | Temp | Humidity
- High Performance Digital Megohmeter Kit
- Measures Surface Resistivity, Resistance, Temperature, Humidity
- Measurement range for 10v resistance is from 103 to 106
- Measurement range for 100v resistance is from 106 to 1012
- Accuracy ±10% at 103 - 108
You may also like…
-
4800 Ultra II Static Dissipative Clear Urethane Floor Finish
- Coverage 1,500 - 2,000 sq'/gallon
- Strip cycle 12 -18 months
- Suitable to use on ESD tile, epoxy and concrete floors
- Surface resistivity: 107 - 109 ohms per square (average)
- Low voc
-
4600 Ultra Static Dissipative Clear Urethane Floor Finish
- High performance with exceptional static control
- For Use on vinyl, linoleum, or ceramic tile
- Offers high gloss, slip resistant & abrasion resistant finish
- More economical than other leading ESD floor finishes
- Resists powdering or flaking, even in dry condidtions
-
4010 Acrylic ESD Floor Stripper Concentrate
- Prepares floor for application of acrylic based ESD floor finishes
- No ammonia or phosphates
- Effective in hard or soft water
- Low 6% V.O.C.
- Zero tribogeneration

















