NE258P Novolac Epoxy Clear Primer Acid Solvent Chemical Resistant Floor Coating
Starting at $55.00
- Excellent primer companion to our NE256 Novolac Clear Epoxy topcoat
- Helps reduce air release generation when applying higher solids novolac topcoats
- Outstanding Spill and Splash Acid, Solvent, Chemical surface protection
- Resists wide range of chemicals, solvents and acids
- Excellent adhesion 365 psi
Overview
- Description
- Additional Information
- Specs
- Coverage Rate
- Cure
- Chemical
- Application
- Calculator
NE258P Novolac Clear Epoxy Primer Chemical Resistant
NE258P is a two component novolac clear epoxy primer with exceptional resistance to a variety of chemicals, solvents and acids designed for application as part of a protective coating system where splash and spills of acids, chemicals, and solvents occur. NP258P offers high solids, good substrate penetration and low odor.
The NE258P primer reduces air release generation from the substrate when applying higher solids novolac epoxy topcoats such as NE256. Recommended for priming concrete and cement substrates prior to applying other novolac topcoats. This will result in fewer surface imperfections in high build and self leveling type coating.
Available in 1 quart kit, 1.5 gallon kit, 3 gallon and 15 gallon kits in a clear (gardner 1-2)
PRIMER: None required
TOPCOAT: Many novolac products are suitable including our NE256 Novolac Clear Epoxy
Where is the NE258P used?
- Chemical process plants
- Pulp and paper mills
- Food processing
- Gas processing
- Power generation
- Sewage and water treatment
- Battery charging stations
- Mining industry
- Manufacturing plants
- Chemical storage areas
- Areas subject to chemical exposure
- Warehouse loading dock areas
- Concrete and brick surfaces subject to chemical spill and splash conditions
Why NE258P Novolac Epoxy Primer?
- Excellent primer companion to our NE256 Novolac Clear Epoxy topcoat
- Helps reduce air release generation when applying higher solids novolac topcoats
- Outstanding Spill and Splash Acid, Solvent, Chemical surface protection
- Resists wide range of chemicals, solvents and acids
- Excellent adhesion 365 psi
- Long working time with 1 to 3 hour POT life
| Weight | 165 lbs |
|---|---|
| Dimensions | N/A |
SPECIFICIATIONS |
|
|---|---|
| Solids | By Weight 62% By Volume 58% |
| VOC | 335 g/L mixed |
| Colors | clear (gardner 1-2) |
| Recommended Film Thickness | 5-6 mils per coat wet thickness (yiels 2-3 mils dry) |
| Coverage per Gallon | 267 to 320 square feet @2-3 mils wet thickness |
| Packaging | 3 gallon kit and 15 gallon kit |
| Mix Ratio | (2:1 mix ratio) 2 gallons part A to 1 gallons part B |
| Shelf Life | 1 year in unopened container |
| Finish | Gloss (>30 at 60 degrees @Erichsen glossmeter) |
| Abrasion Resistance | Taber abraser CS-17 calibrase wheel with 1000 gram total load and 500 cycles= 25.7 mg loss |
| Flexibility | No cracks on a 1/8″ mandrel |
| Impact Resistance | Gardner Impact, direct = 50 in lb (passed) |
| Adhesion | 365 psi @elcometer (concrete failure, no delamination) |
| Viscosity | Mixed = <200 cps (typical) |
COVERAGE RATE
| Coverage Per Gallon | 267 To 320 Square Feet @2-3 Mils Wet Thickness |
CURE SCHEDULE
| Pot Life – (1-1/2 gallon volume) | 1-3 hours |
| Tack free (dry to touch) | 4-7 hours |
| Recoat or topcoat | 7 – 10 hours |
| Light foot traffic | 12-24 hours |
| Full cure (heavy traffic) | 2-7 days |
APPLICATION TEMPERATURE: 60-90 degrees F with relative humidity below 90%
CHEMICAL RESISTANCE |
RATING |
|---|---|
| Xylene | D |
| 1.1.1 trichlorethane | C |
| MEK | C |
| Methyl Alcohol | C |
| Toluene | D |
| 10% sodium hydroxide | E |
| 50% sodium hydroxide | E |
| 10% sulfuric acid | E |
| 10% hydrochloric acid | C |
| 20% nitric acid | D |
| Ethylene glycol | E |
| Acetic acid 5% | D |
| Gasoline | D |
Rating key: A – not recommended, B – 2 hour term splash spill, C – 8 hour term splash spill, D – 72 hour immersion, E – long term immersion.
MIXING AND APPLICATION INSTRUCTIONS
PRODUCT STORAGE: Store product in an area so as to bring the material room temperature before using. Continuous storage should be between 60 and 90 degree F. Low temperatures or great temperature fluctuations may cause product crystallization.
SURFACE PREPARATION: Surface preparation will vary according to the type of complete system to be applied. For a one or two coat thin build system (3-10 mils dry) we recommend either mechanical scarification or acid etching until a suitable profile is achieved. For a complete system build higher than 10 mils dry, we recommend a fine brush blast (shot blast). All dirt, oil, dust, foreign contaminants and laitance must be removed to assure a trouble free bond to the substrate. A test should be made to determine that the concrete is dry; this can be done by placing a 4’X4’ plastic sheet on the substrate and taping down the edges. If after 24 hours, the substrate is still dry below the plastic sheet, then the substrate is dry enough to start coating. The plastic sheet testing is also a good method to determine if any hydrostatic pressure problems exist that may later cause disbonding.
PRODUCT MIXING: Each 3 gallon kit of this product has a mix ratio of 2 gallons Part A to 1 gallon B by volume. Standard packages are in pre-measured kits and should be mixed as supplied in the kit. Before the two components are mixed together, mix the part A and part B separately to insure they are uniform before they are combined. After the two parts are combined, mix well with slow speed mixing equipment (recommend jiffy mixer) until the material is thoroughly mixed and streak free. This material has a high viscosity – mix well.
Improper mixing may result in product failure. For best mixing results and proper blending of parts A and B, recommend a Jiffy Mixer style drill mixer.
****IMPORTANT NOTE AFTER MIXING:****
Once parts A&B are thoroughly mixed, immediately pour 100% of all mixed product on the floor in a ribbon pattern, S or W shape over the area you want that amount of product to cover. The risk of leaving product in the bucket is that it will become hard and reduce the working time by a minimum of 50% and may harden and start smoking in the bucket before you get back to it.
PRODUCT APPLICATION: The mixed material can be applied by brush or roller. Maintain temperatures and humidity within the recommended ranges during the application and curing process. Improper mixing or applying the product too thick may result in product failure.
RECOAT OR TOPCOATING: This product is a primer, we recommend a topcoat. When you recoat or topcoat this product, you must first be sure that all of the solvents have evaporated from the coating during the curing process.Refer to the cure schedule as a guideline to follow, in addition we strongly recommend to test the coating before recoating or topcoating. This is done by pressing your thumb on the coating in multiple places to ensure a fingerprint impression is not visible. If there is no impression visible, then coating the floor can be done. Note, colder or hotter than 75 degrees can affect the curing time schedule Before recoating or topcoating, check the coating to insure no epoxy blushes were developed (a whitish, greasy film, or deglossing.) If a blush is present, it can be removed with any standard type detergent cleaner prior to topcoating or recoating. The primary choice of topcoat will be other novolac epoxy coatings. Multiple coats of this product are suitable prior to topcoating. 7)
CLEANUP: Use xylol.
FLOOR CLEANING: Caution! Some cleaners may affect the color of the floor installed. Test each cleaner in a small area, utilizing your cleaning technique. If no ill effects are noted, you can continue to clean with the product and process tested.
RESTRICTIONS: Restrict the use of the floor to light traffic and non-harsh chemicals until the coating is fully cured (see technical data under full cure). It is best to let the floor remain dry for the full cure cycle. Dependent on actual complete system application, surface may be slippery, especially when wet or contaminated; keep surface clean and dry.
LIMITATIONS:
- Colors may be affected by high humidity, low temperatures or chemical exposure.
- For best results use a 3/8” nap roller.
- Substrate temperature must be 5°F above dew point.
- All new concrete must be cured for at least 30 days prior to application.
- This product should be topcoated with a suitable novolac epoxy topcoat.
- Colors may vary from batch to batch.
- All new concrete must be cured for at least 30 days prior to application.
- Physical properties are typical values and not specifications.
NOTICE TO BUYER: DISCLAIMER OF WARRANTIES AND LIMITATIONS ON OUR LIABILITY We warrant that our products are manufactured to strict quality assurance specifications and that the information supplied by us is accurate to the best of our knowledge. Such information supplied about our products is not a representation or a warranty. It is supplied on the condition that you shall make your own tests to determine the suitability of our product for your particular purpose. Any use or application other than recommended herein is the sole responsibility of the user. Listed physical properties are typical and should not be construed as specifications. NO WARRANTY IS MADE, EXPRESSED OR IMPLIED, REGARDING SUCH OTHER INFORMATION, THE DATA ON WHICH IT IS BASED, OR THE RESULTS YOU WILL OBTAIN FROM ITS USE. N0 WARRANTY IS MADE, EXPRESSED OR IMPLIED, THAT OUR PRODUCT SHALL BE MERCHANTABLE OR THAT OUR PRODUCT SHALL BE FIT FOR ANY PARTICULAR PURPOSE. NO WARRANTY IS MADE THAT THE USE OF SUCH INFORMATION OR OUR PRODUCT WILL NOT INFRINGE UPON ANY PATENT. We shall have no liability for incidental or consequential damages, direct or indirect. Our liability is limited to the net selling price of our product or the replacement of our product, at our option. Acceptance of delivery of our product means that you have accepted the terms of this warranty whether or not purchase orders or other documents state terms that vary from this warranty. No representative is authorized to make any representation or warranty or assume any other liability on our behalf with any sale of our products. Our products contain chemicals that may CAUSE SERIOUS PHYSICAL INJURY. BEFORE USING, READ THE SAFETY DATA SHEET AND FOLLOW THE PRECAUTIONS TO PREVENT BODILY HARM.
Square Footage Calculator
Estimate the Right Amount for Your Project
Use the calculator to determine your total project square footage. Once you have your measurements, compare the result to the product coverage rate listed on this page to estimate how much material you'll need for complete coverage.
Calculate Coverage
Quickly determine the total square footage of your project area.
Estimate Product Quantity
Use your results to calculate how much product your project requires.
Plan With Confidence
Add a waste percentage to account for surface texture and application conditions.
Coverage estimates are provided as a general guide. Actual product usage may vary based on surface condition, porosity, application method, and project requirements.
Recommended Tools
-

Jiffy Mixer for Epoxy, Polyaspartic, Urethane & High Viscosity Liquids | Stainless | Minimize Air
- Properly Mix High Viscosity Liquids (not just stir)
- Required Tool for Mixing Epoxy, Urethane, Polyaspartic Coatings
- Mix Foams, Glues, Mortars, Paints, Resins, Cement, Chemicals
- Heavy Duty Construction For Industrial/Commercial Projects
- Made of 304 polished stainless steel,
-

Spike Shoes | Walk on Wet Epoxy, Polyaspartic, Urethane Floor Coatings
Starting at $45.99 -

Spike Shoes – Flexible | Walk on Wet Epoxy, Polyaspartic, Urethane Floor Coatings
Starting at $175.00 -

Spike Shoes | Economical | Walk on Wet Epoxy, Polyaspartic, Urethane Floor Coatings
Starting at $34.99 -

24″ Notched Floor Squeegee 3/16″ Deep For Epoxy & Polyaspartic Coatings
- 24" Speed Squeegee, 3/16" notch, Threaded Handle Adapter
- For Quicker and Easier Application of thicker mil (thickness) floor coating systems
- A floor coating standard, just grab it,use it, and toss it or clean it
- This one has our own special twist, a threaded handle adapter
- Features an aluminum frame with a red rubber solvent resistant blade
-

24″ Flat Floor Squeegee For Epoxy & Polyaspartic Coatings
- 24" Speed Squeegee
- For Quicker and Easier Application of thicker mil (thickness) floor coating systems
- A floor coating standard, just grab it,use it, and toss it or clean it
- Light weight, high performance, re-usable plastic floor squeegee
- Makes installing floors a breeze
-

18″ Wooster Pro Doo Z Cover For Epoxy, Urethane, Polyaspartic Coatings | 6/Box | 2 Sizes
- Shed resistant woven fabric for a virtually lint free finish with all paints, enamels, primers, urethanes, and epoxies.
- Available in 3/8" and 3/4" thick nap roller covers
- Exclusive golden pinstripe design stays resilient, resists matting.
- Green double thick polypropylene core resists water, solvents, and cracking.
- Sold in Boxes of 6 Sleeves
-

18″ Wooster Big Ben Roller Frame For Quick Application of Floor Coatings
- 18" Big Ben Roll Frame
- For 18" Roller Covers, 1-1/2" Standard Or 2-1/4" Jumbo Diameter
- Lightweight Yet Strong Polypropylene Construction
- Quickly Install Or Remove The Roller Cover
- For 18 Inch roller covers with 1 1/2 Inch standard or 2 1/4 Inch jumbo Diameter and can be used with all nap heights
You may also like…
-

NE257P Novolac Epoxy Colored Primer Acid Solvent Chemical Resistant Fl
- Excellent primer companion to our NE253 and NE253SL Novolac Epoxy topcoats
- Outstanding Spill and Splash Acid, Solvent, Chemical surface protection
- Resists wide range of chemicals, solvents and acids
- Excellent adhesion 375 psi
- Long working time with 1 to 3 hour POT life
-

NE253 Novolac Colored Epoxy Acid Solvent Chemical Resistant High Build
- Outstanding Spill and Splash Acid, Solvent, Chemical surface protection
- Resists wide range of chemicals, solvents and acids
- Resistant to high concentrations of acids and even some chlorinated solvents
- High build for heavy duty traffic projects, chemical troughs and curbs
- Great for tanks and chemical spill areas for cement, masonry or brick
-

NE256 Novolac Clear Epoxy Acid Solvent Chemical Resistant Floor Coating
- Outstanding Spill and Splash Acid, Solvent, Chemical surface protection
- Exceptional resistance to wide range of chemicals, solvents and acids
- Medium to High build for chemical spill areas, troughs, curbs and tanks
- Use as coating or chip/flake or aggregate systems
- Excellent adhesion 400 psi