Color-Lok Solid Color Acrylic Siloxane Stain Offers Commercial Grade Performance

Rainguard Color-Lok™ Acrylic Siloxane Solid Color Stain is a premium quality, modified acrylic penetrating stain fortified with siloxane for use on concrete, masonry and wood surfaces.  It offers excellent color and enhanced moisture protection. The addition of ultraviolet light absorbers, color stabilizers and penetrating agents dramatically improve adhesion and its resistance to the chipping, cracking and flaking of traditional exterior paints, ensuring long lasting performance. The deep penetrating formula does not change surface texture, maintaining the natural look and texture of the surface.

It is easy to apply and is used in a wide range of commercial and residential projects. Color-Lok™ Solid Color Stain adds water repellency to whatever surface it is applied to.

Comes in 2 mfg pre-mixed colors or create your own custom color using one of 3 available tint bases: pastel, accent & deep. Custom colors require mixing with standard water based colorant used to tint acrylic household paints.  Available in both semi-transparent and solid color formulations.

Where is Color-lok used?

  • Construction & Remodel Projects:   Commercial building exterior walls, floors subject to light to medium foot traffic
  • Homeowner projects:  Exterior walls, decks, patios, porches, fences, outdoor furniture

Why Color-lok Solid Color Stain?

  • 5 year labor and material warranty
  • Exclusive Micro-lok penetrating formulation
  • Does not change the look of the surface texture
  • Rich uniform look dries to dead flat finish minimizes flashing, lap marks
  • Superior moisture control performance
  • Breathable – does not trap moisture
  • Apply down to 40°F (4.4°C)
  • Quick 2 hour recoat time
  • Highly resistant to UV rays
  • Mix with Micro-seal for additional transparency to customize the look
  • For horizontal surfaces, best performance when top coated with Rainguard Satin-lok Acrlyic Sealer or Clear-seal Urethane Sealer for added clear protection
  • 100% Eco-friendly: low VOC


TECHNICAL INFORMATION

Color Mfg colors or Use one of 3 tint bases to make your own color using water based colorant compatible with acrylic paint
Sheen/Gloss Level Flat Sheen
Dry To Re-Coat 2 hours
#Coats Recommended 1 – 2 coats
Back in-service time 24 hours to walk-on
Application method Low pressure hand pump or airless sprayer, brush, roller
Where Can it be Used All Interior|Exterior architectural surfaces
Apply to New Concrete 10 days
Low Application Temperature 40F|4.4C Surface & Air
 Base  Water
VOC Content <50 g/L
Use on Material All masonry, concrete and wood surfaces
Warranty Available 5 year warranty available –  download warranty application to register, see DOCUMENTS tab above

Certification/Test
Leed 4.2 (1) point credit available Meets LEED and SQAMD low VOC requirements
COVERAGE RATE SQUARE FEET/GALLON
Porous Surfaces 125 – 175
Dense Surfaces 150 – 200
*Textured surfaces Decreases coverage rates

APPLICATION INSTRUCTIONS

CONDITIONS PRIOR TO APPLICATION
Temperature (surface|air) 50F to 90F (10C to 35C) and at least 5F above dew point
Moisture of substrate Less than 15%
Humidity Less than 90%
Rain No rain 48 hrs prior to, 48 hrs after application
Cure time for newly poured concrete Apply 10 days after pour
Application method Use low pressure hand pump or garden sprayer, t-bar, brush, lambs wool applicator

FOLLOW THESE SIMPLE APPLICATION STEPS
1.  Rainguard COLOR-LOK is best and most economically ap-plied using commercial airless spray equipment set at moderate pressures using a tip of .015 to .021. For appli-cation to horizontal surfaces, materials may be sprayed or rolled using a short nap roller. Back rolling may be necessary to even the applied finish.
Spray apply one coat of COLOR-LOK to surfaces at the suggested rates depending on color, surface type, and porosity. To avoid lap marks, maintain a continuous wet edge. Feath er edges at the end of each pass. Stop appli-cation only at control joints, corners, and edges. If a “heavier” painted look is needed, apply additional coats.

2. All surfaces to be coated should be structurally sound, clean, and dry. Kill mold, mildew, and fungus using com-mercially available cleaners or a 50/50 mix of bleach and water. Make sure all residue is rinsed prior to coating application.

3.  Mix contents thoroughly prior to application. To prevent skinning, cover pail with a damp cloth.

PRECAUTIONS & LIMITATIONS
1. All surfaces to be coated should be clean of any dirt and grime, efflorescence, lime run, form oils and release agents, grease, mud, excess mortar, and mold and mildew, etc.
2. All cracks should be pointed or caulked. All voids, bee holes, masonry surface defects and openings such as conduits, pipes, drains, door frames, vents, air conditioner openings, electrical openings, control joints, or any dissimilar materials should be repaired using urethane or other approved patching.

STORAGE
Store materials in a well-protected area between 45° and 90°F. Avoid freezing temperatures, direct sunlight, and moisture. Keep away from heat sources.