Aspartic 100 High Build Polyaspartic Coating | Low Temp 30°F

Aspartic 100 is a two component, 100% solids, high build low temp polyaspartic aliphatic coating designed as an extremely tough, durable and decorative topcoat to protect high performance epoxy floor concrete coating systems.

Aspartic 100 offers excellent abrasion and chemical resistance, is UV Stable, and has a beautiful, extremely clear, high gloss appearance available in 14 colors.  Aspartic 100 offers more working time and yet still allows quicker back in service times than traditional epoxy or urethane coatings with back in-service times of 10-14 hours for light foot traffic at 70°F and heavy traffic full service in 24-48 hours.

Aspartic 100 can be applied in cold weather down to 30°F.  (cold temperatures will significantly slow down recoat and back in-service times).

Aspartic 100 is sold in 30 oz trial size kits, 3 gallon and 15 gallon kits. It comes in clear or can be tinted with one of 14 Pigmented Colors (pigment sold separately by the quart).  Pre-pigmented Aspartic 100 available by special order with purchase of 60 gallons or more.

The spread rate of the Aspartic 100 Clear as a clear topcoat over a smooth surface apply at 350 – 400 sq’/gallon and as a pigmented topcoat over a smooth surface apply at 250 to 350 sq’/gallon and over a full broadcast flake floor, it is 130-160 sq.ft. per gallon.  Can be applied as thick as 16 mils or 100 sq’/gallon in one coat, typically done as clear topcoat over full broadcast of quartz granules saving time over a typical 2 coat application of high solids polyaspartics..

Aspartic 100 is not recommended for application direct to concrete but designed for application over interior epoxy systems with solid colors, flakes and quartz granules.  Not recommended for outdoor projects.

PRIMER: Recommended as topcoat to high performance epoxy systems

TOPCOAT: None recommended.  Can apply multiple coats of Aspartic 100.

 Where is Aspartic 100 Low Temp Polyaspartic used?

  • Concrete floors or countertops
  • Warehouse and commercial office floors
  • Kitchens

Why Aspartic 100 Low Temp Polyaspartic?

    • Tough, durable topcoat for interior epoxy floor coatings
    • Very low to no odor great for sensitive odor indoor projects
    • Can be used as high build topcoat up to 16 mils or 100 sq’/gallon
    • Cold temperature application down to 30°F
    • Excellent chemical and abrasion resistance
    • UV Stable and will not yellow
    • Beautiful high gloss appearance
    • Designed for high traffic and industrial areas
    • 100% Solids Performance
    • Available in clear & 14 colors!

Pigment Sold Separately by the Pint - Mix Pigment With Aspartic 100 Prior to Application

Beautiful Color Line To Enhance Your Flooring Projects. Our Polyaspartic Pigment Is Sold In 32 Oz Quarts.  Easy To Use,  Just Pour And Blend.  Add 6-10 Oz Per Mixed Gallon Of Liquid, Depending On Desired Color.  For A More Richer, Deeper Color, Add 10 Oz Of Pigment Per Mixed Gallon Of Our Polyaspartic.  Each 32 oz Quart Of Pigment Colors 3-5 Gallons Of Floorguard Products Polyaspartic.

SPECIFICATIONS

Solids By Weight 100%   By Volume 100%
VOC  0 g/L
Colors  Clear + 14 colors.  See color chart
Recommended Film Thickness  3 – 8 mils most applications
Coverage per Gallon  100-500 sq’/gal
Packaging 3 gallon kit, 15 gallon kit
Mix Ratio 2:1 by volume (3 gal kit = 2 gal part A & 1 gal part B)
Self Life 6 months in unopened container
Finish High gloss >70 at 60 degrees
Abrasion Resistance Taber abrasion CS-17 calibrase wheel with 1000g total load & 500 cycles= 20.0 mg loss
Viscosity <1,000 centipose typical
Ultimate Elongation 2.4%
Compressive Strength >12,000 psi @ASTM D695
Tensile Strength >3,900 psi @ASTM D638
Hardness Shore D=80

COVERAGE RATE

Coverage Per Gallon  100-500 Sq’/Gal

CURE SCHEDULE (70°F)

Usable working time 20-30 minutes
Tack free (dry to touch) 5-7 hours
Recoat or topcoat 8-10 hours
Light foot traffic 10-14 hours
Full cure (heavy traffic) 24-48 hours

APPLICATION TEMPERATURE: 30-90 degrees F with relative humidity below 90%

CHEMICAL RESISTANCE

RATING
 Acetic acid 5% C
 Xylene C
 Mek A
 skydrol C
 Ethyl alcohol B
 50% sodium hydroxide E
 10% sulfuric acid C
1.1.1 trichloroethane B
 10% Hydrochloric Acid C
Methanol B

Rating key: A – not recommended, B – 2 hour term splash spill, C – 8 hour term splash spill, D – 72 hour immersion, E – long term immersion.

MIXING AND APPLICATION INSTRUCTIONS

PRODUCT STORAGE: Product must be stored in an area that will bring the product to room temperature prior to using. Continuous storage should be between 60 and 90 degree F. Keep from freezing

SURFACE PREPARATION: Preparation methods may vary depending on the system being applied. For a complete system thickness that is higher than 10 mils dry, a fine brush blast (shot blast), is recommended. To assure a trouble free bond, all dust, oil, dirt, foreign contaminants and laitance must be removed. It is recommended to perform a moisture test to determine that the concrete has an appropriate vapor barrier. This can be done by placing a 4’X4’ plastic sheet on the substrate and taping down the edges. Once 24 hours has passed, and the substrate is still dry below the plastic sheet, then the substrate does not show signs of eventual hydrostatic pressure problems that may later cause disbonding. This test does not guarantee, however, that there may not be future hydrostatic pressure issues in the future.

PRODUCT MIXING: This product has a two to one mix ratio by volume-merely mix two gallons of part A with one gallon of part B. After the two parts are combined, mix well with slow speed mixing equipment until the material is thoroughly mixed and streak free. Avoid whipping air into the coating.  When pigmenting the product (ex. making a 3 gallon batch), pour 1 gallon of Part B into a measuring/mixing bucket, then add the desired amount of pigment into the Part B and mix until blended. Then add the part A up to the 3 gallon mark and mix and blend very well until material is thoroughly mixed and streak free. Improper mixing may result in product failure.

For best mixing results and proper blending of parts A and B, recommend a Jiffy Mixer style drill mixer.

PRODUCT APPLICATION: It is recommended to dip and roll this product using a 3/8” nap roller cover. It is best to maintain a wet edge to avoid roller marks. Direct sunlight or high temperatures may cause visible roller making during application. Applying the product too thick may result in solvent entrapment and product failure. Relative humidity can have a dramatic influence on the curing characteristics. The product will dry quicker and have less working time when the relative humidity is higher while a lower relative humidity will lengthen the dry time and working time. This product has a short usable pot life of about 15 minutes which is substantially shorter than the actual gel time for the product. Applying the product beyond the usable pot life can result in surface irregularities.

RECOAT OR TOPCOATING:Installing multiple coats of this product is acceptable. If recoating this product, be sure that all of the solvents have evaporated from the coating during the curing process. Refer to the cure schedule as a guideline to follow, however it is best to test the coating before recoating or topcoating. This is done by pressing your thumb on the coating to ensure a fingerprint impression is not visible. If there is no impression visible, then coating the floor can be done. Note, colder temperatures require longer cure times before product can be recoated. Prior to coating the floor, make sure there are no contaminants exist. If contaminants or a blush exists, remove with a standard detergent cleaner and ensure floor is clean and dry prior to coating. It is recommended to degloss the previous floor prior to coating to ensure a trouble free bond.

CLEANUP/FLOOR CLEANING:Use solvents for cleanup. When cleaning the floor, CAUTION! Some cleaners may affect the color of the installed floor. Test each cleaner used in a small area, ensuring no damage occurs. Restrict the use of the floor to light traffic and non-harsh chemicals until the floor is fully cured, refer to the cure schedule. Allow the floor to remain completely dry during the curing process.

RESTRICTIONS: Restrict the use of the floor to light traffic and non-harsh chemicals until the coating is fully cured (see technical data under full cure). It is best to let the floor remain dry for the full cure cycle. Dependent on actual complete system application, surface may be slippery, especially when wet or contaminated; keep surface clean and dry.

LIMITATIONS:

  • Colors or gloss may be affected by high humidity, low temperatures, chemical exposure, or exposure to lighting such as sodium vapor lights.
  • Installing product too thick may result in surface imperfections, bubbles, or product failure
  • Do not expose this product to water until fully cured
  • Substrate temperature must be 5°F above dew point
  • All new concrete must be cured for at least 30 days
  • Physical properties are typical values and not specifications
  • Light or bright colors (white, safety yellow, etc. may require multiple coats or a suitable color coordinated primer to achieve a satisfactory hide
  • Always apply a test patch to determine product suitability and adhesion performance for your proposed application method and procedures
  • Colors may vary from batch to batch, therefore use only product from the same batch for an entire job
  • Physical properties listed on this technical data sheet are typical values and not specifications.

NOTICE TO BUYER: DISCLAIMER OF WARRANTIES AND LIMITATIONS ON OUR LIABILITYFloorguard Products® warrants that our products are manufactured to strict quality assurance specifications and that the information supplied by us is accurate to the best of our knowledge. Such information supplied about our products is not a representation or a warranty. It is supplied on the condition that you shall make your own tests to determine suitability of our product for your particular purpose. Listed physical properties are typical and should not be construed as specifications. NO WARRANTY IS MADE, EXPRESSED OR IMPLIED, REGARDING SUCH OTHER IFNORMATION, THE DATA ON WHICH IT IS BASED, OR THE RESULTS YOU WILL OBTAIN FROM ITS USE. NO WARRANTY IS MADE, EXPRESSED OR IMPLIED, THAT OUR PRODUCT SHALL BE MERCHANTABLE OR THAT OUR PRODUCT SHALL BE FIT FOR ANY PARTICULAR PURPOSE. NO WARRANTY IS MADE THAT THE USE OF SUCH INFORMATION OR OUR PRODUCT WILL NOT INFRINGE UPON ANY PATENT. We shall have no liability for incidental or consequential damages, direct or indirect. Our liability is limited to the net selling price of our product or the replacement of our product, at our option. Acceptance of delivery of our product means that you have accepted the terms of this warranty whether or not purchase orders or other documents state terms that vary from this warranty. No representative is authorized to make any representation or warranty or assume any other liability on our behalf with any sale of our products. Our products contain chemicals that may CAUSE SERIOUS PHYSICAL INJURY. BEFORE USING, READ THE MATERIAL SAFETY DATA SHEET AND FOLLOW ALL PRECAUTIONS TO PREVENT BODILY HARM.