Return to previous page
  • Overview
  • Specs
  • Coverage Rate
  • Application

Super Stucco Sealer Stops a 98 mph Wind Driven Rain on Stucco Walls

Super Stucco Sealer Primer is a specially designed water based, clear silane siloxane water repellent sealer to protect stucco, EIFS and cement plaster.

It works. It’s been tested to stop a 98 mph wind driven rain coming through a wall treated with Super Stucco Sealer. It does this without changing the look or texture of the surface with a clear, penetrating performance. Super Stucco can also be used as a primer prior to application of a paint or latex stain topcoat.

Super Stucco™ penetrates deep into dense masonry surfaces to provide long lasting and virtually indestructible water repellent protection that is not affected by weather or sunlight that contains no silicone oils, parafin wax or urethanes. One gallon concentrate makes 10 gallons ready-to-use product.

Where is Super Stucco used?

  • Construction & Remodel Projects:   Exterior building stucco, EIFS and plaster walls
  • Homeowner projects:  Exterior stucco and plaster walls

Why Super Stucco Sealer?

  • 5 year labor/material warranty available
  • Easy to use Concentrates
  • ASTM tested for superior performance in stopping water damage
  • 100% Eco-friendly: low VOC
  • Excellent mold and mildew inhibitor
  • Does not alter surface appearance & UV resistant – will not yellow
  • Overspray during application will not harm glass or other building surfaces
  • Comparison Chart of Concrete Sealers by ConcreteNetwork.com


TECHNICAL INFORMATION

Color Clear, No change in appearance or surface texture
Sheen/Gloss Level None
Dry To Re-Coat 30-60 Minutes
#Coats Recommended 1 (2 coats if especially porous)
Application method Low pressure hand pump or airless sprayer
Where Can it be Used  Vertical unpainted, porous surfaces
Apply to New Stucco 48 hours
Low Application Temperature 35F|1.7C Surface & Air
 Base  Water
VOC Content <15 g/L
Use on Material Concrete, masonry, stucco,  EIFS
Warranty Available 5 years labor/material warranty –  download warranty application to register, see DOCUMENTS tab above

 

CERTIFICATION/TEST
Leed 4.2 (1) point credit available Meets LEED and SQAMD low VOC requirements
ASTM D-1653 Water Vapor Transmission Rate 100% Vapor Permeable
ASTM E-514 Wind Driven Rain passed 98 mph (160 kph) 96.2% leak reduction
ASTM C67-87 Water Repellency 97% Effective
ASTM G-53 Weathering 2500 hours – no change
NCHRP No 244 Series IV Salt Pounding 87% reduction

 

COVERAGE RATE SQUARE FEET/GALLON
Stucco 150 – 200
EIFS 75 – 100
Clay Tile 100 -150
Cement Plaster 100 – 150
Clay Block 100 – 150
Cast Concrete 150 – 175
*Textured surfaces Reduce coverage rates

APPLICATION INSTRUCTIONS

CONDITIONS PRIOR TO APPLICATION
Temperature (surface|air) 35F to 90F (1.7C to 35C) and at least 5F above dew point
Moisture of substrate Less than 15%
Humidity Less than 90%
Rain No rain 48 hrs prior to, 12 hrs after application
Cure time for newly poured concrete Apply 48 hrs after pour
Application method Use low pressure hand pump or garden sprayer

WORKING WITH CONCENTRATES

PART # SIZE MAKES INSTRUCTIONS
CR-0300 1 Gal 10 Gal Measure concentrate needed, mix with water, stir (use 9 parts water to 1 part Super Stucco)

 

FOLLOW THESE SIMPLE APPLICATION STEPS
1. SUPER STUCCO should be applied using low-pressure airless or hand pump spray equipment
2. Do not atomize material (don’t want product to spray as a mist) as it will negatively impact product performance. For power sprayers, use large tip size of at least .035 to .051. For hand pump sprayers, turn spray nozzle at end of the spray wand so product flows out more like a steady stream and keep pressure up to amke sre enough material is coming out. Spray head should be held 8 to 12 inches from the surface so material floods down the wall at least 6-12 inches below the point of application.  For quickest application rate and to ensure a completely saturated surface suggest on powered spray equipment, remove the spray tip and on hand pump sprayers, remove the wand/tip. Product will flow very quickly, in a steady stream and completely eliminate atomizing.
3. Avoid application in windy weather.
4. Trigger gun off at the end of each pass to avoid using excessive materials. Stop all applications only at corners, joints, seams, or edges.
5. Multiple coats may be applied, whiting or yellowing will not occur.  A second coat is best applied “wet on wet” which means apply when first coat is damp but not yet dry.  Use same flood coat procedure.

PRECAUTIONS & LIMITATIONS
1. All surfaces to be coated should be clean of any dirt and grime, efflorescence, lime run, form oils and release agents, grease, mud, excess mortar, and mold and mildew, etc.
2. All cracks should be pointed or caulked. All voids, bee holes, masonry surface defects and openings such as conduits, pipes, drains, door frames, vents, air conditioner openings, electrical openings, control joints, or any dissimilar materials should be repaired using urethane or other approved patching.

STORAGE
Store materials in a well-protected area between 45° and 90°F. Avoid freezing temperatures, direct sunlight, and moisture. Keep away from heat sources.

Reviews